The Cicada Vaccine Forecasting Engine and Guide
0.1.0 - ci-build

The Cicada Vaccine Forecasting Engine and Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

ValueSet: Cicada Data Integrity Value Set

Official URL: http://fhirfli.dev/fhir/ig/cicada/ValueSet/data-integrity-vs Version: 0.1.0
Draft as of 2026-09-02 Computable Name: DataIntegrityVS

Reasons a dose was reported rather than evaluated.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

 

Expansion

Expansion performed internally based on codesystem Cicada Data Integrity Code System v0.1.0 (CodeSystem)

This value set contains 3 concepts

SystemCodeDisplay (en)DefinitionJSONXML
http://fhirfli.dev/fhir/ig/cicada/CodeSystem/data-integrity  dose-before-birthDose dated before the date of birthThe administration date precedes the patient's date of birth, so the dose was not given to this patient. Check the birth date, the administration date, and that the record belongs to this patient.
http://fhirfli.dev/fhir/ig/cicada/CodeSystem/data-integrity  dose-after-assessmentDose dated after the assessment dateThe administration date is after the assessment date, so the administration has not happened. A planned dose belongs in an ImmunizationRecommendation.
http://fhirfli.dev/fhir/ig/cicada/CodeSystem/data-integrity  duplicate-same-dayTwo doses covering one antigen on one dayTwo administered doses covering the same antigen carry the same date. Matched on the antigen, not the product, so it catches a combination given alongside a component — Pediarix and Pentacel are different CVX codes that both carry diphtheria, tetanus, pertussis and polio. Both doses are still evaluated on their own merits; the engine cannot tell a record entered twice from a second injection.

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code